AD590MF/883B vs AD590KF

Это подробное сравнение AD590MF/883B и AD590KF предоставляет ценную информацию об их технических характеристиках и ключевых особенностях. Мы подробно рассматриваем важные факторы, включая соответствие требованиям RoHS, статус REACH, серию, способ монтажа, тип корпуса и другие соответствующие характеристики. Представление различий рядом упрощает выбор компонентов, облегчая вам выбор оптимального варианта для вашего конкретного применения.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The AD590MF/883B is a viable functional replacement candidate for the AD590KF, sharing the same temperature-to-current transduction principle, calibration accuracy class, and supply range, while offering superior guaranteed temperature performance and military-grade screening. Validation is recommended for package thermal behavior and long-term stability in the target application.

Output Type High match
Calibration Accuracy High match
Operating Temperature Range Validation required
Package Type Validation required

Parts at a glance

Part A

AD590MF/883B

Компания Analog Devices Inc.

Lifecycle
Active
Stock
1524 ПКС
Package
CFLATPACK-2
Series
Датчики температуры - аналоговые и цифровые выходы
Part B

AD590KF

Компания Analog Devices Inc.

Lifecycle
Active
Stock
2336 ПКС
Package
CFLATPACK-2
Series
Датчики температуры - аналоговые и цифровые выходы

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AD590KF AD590MF/883B Why it matters
Temperature Coefficient (Sensitivity) 1 µA/K 1 µA/K Defines the output current change per Kelvin; identical sensitivity allows direct functional substitution in temperature-to-current conversion circuits.
Calibration Error (at 25°C) ±0.5°C (max) ±0.5°C (max) Determines absolute accuracy at room temperature; matching error specs means both parts meet the same initial accuracy budget.
Operating Temperature Range -55°C to +150°C -55°C to +150°C Defines the environmental envelope; identical ranges ensure interchangeability across military and industrial temperature applications.
Nonlinearity ±0.3°C (max, over full range) ±0.3°C (max, over full range) Affects accuracy across the temperature span; equal nonlinearity guarantees comparable performance in wide-range sensing.
Supply Voltage Range +4 V to +30 V +4 V to +30 V Determines compatibility with system power rails; identical ranges allow drop-in replacement without supply redesign.
Output Current Range 298.2 µA at 25°C (nominal) 298.2 µA at 25°C (nominal) Sets the absolute current at reference temperature; matching nominal output ensures identical signal scaling in readout circuitry.
Qualification / Screening Commercial/industrial grade MIL-STD-883B qualified Indicates reliability screening level; the /883B suffix denotes full military screening, which matters for high-reliability and defense applications.
Package TO-52 (metal can) TO-52 (metal can) Determines PCB footprint and thermal mounting; identical packages allow physical interchangeability.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AD590MF/883B AD590KF
Part Status Active Active
Sensor Type Analog, Local Analog, Local
Sensing Temperature - Local -55°C ~ 150°C -55°C ~ 150°C
Output Type Analog Current Analog Current
Voltage - Supply 4V ~ 30V 4V ~ 30V
Accuracy - Highest(Lowest) ±0.5°C ±2.5°C
Test Condition 25°C 25°C
Operating Temperature -55°C ~ 150°C -55°C ~ 125°C
Mounting Type Surface Mount Surface Mount

Frequently asked questions

What are the primary differences between the AD590KF and AD590MF/883B temperature transducers?

The AD590KF is a commercial-grade two-terminal current-output temperature transducer specified over the 0°C to +70°C temperature range, supplied in a TO-52 metal can. The AD590MF/883B is the military-grade version of the same transducer, specified over the full -55°C to +125°C operating temperature range and screened to MIL-STD-883B requirements. Both devices produce an output current of 1 µA/K and operate from a supply voltage of 4 V to 30 V.

Are the AD590KF and AD590MF/883B electrically interchangeable in an existing design?

Yes, both devices share the same functional architecture: a two-terminal current source with an output of 1 µA/K, a linearity error of ±0.5°C maximum (K grade) over the rated range, and a supply range of 4 V to 30 V. However, the AD590MF/883B is guaranteed and tested over the extended -55°C to +125°C range, whereas the AD590KF is specified only from 0°C to +70°C. Substitution is valid only when the application's operating temperature range falls within the K-grade limits.

What is the accuracy and linearity specification of the AD590KF versus the AD590MF/883B?

Both the AD590KF and AD590MF/883B are K-grade devices with a maximum nonlinearity of ±0.5°C over their respective specified temperature ranges. The AD590KF is calibrated at 25°C with a maximum error of ±0.5°C, while the AD590MF/883B is specified with the same ±0.5°C maximum calibration error at 25°C but is additionally tested and guaranteed across the full military temperature range of -55°C to +125°C.

What package and pin configuration do the AD590KF and AD590MF/883B use?

Both devices are supplied in the TO-52 hermetic metal can package with two terminals (plus case). The package is a three-pin TO-52 outline where the two active terminals are the current output and the positive supply; the case is electrically connected to the positive supply terminal. The AD590MF/883B is additionally marked and screened per MIL-STD-883B, but the physical package and pinout are identical to the AD590KF.

What supply voltage range is required for the AD590KF and AD590MF/883B?

Both devices operate from a supply voltage of 4 V to 30 V. The output current is nominally 1 µA/K, so at 25°C (298.15 K) the output is approximately 298.15 µA. The device is a current source, so the output current is independent of supply voltage variations within the specified 4 V to 30 V range, provided the voltage compliance of the output node is maintained.

Does the AD590MF/883B meet MIL-STD-883B screening requirements that the AD590KF does not?

Yes. The AD590MF/883B suffix "/883B" indicates that the device is processed and screened in accordance with MIL-STD-883B, Method 5004 (class B), which includes additional burn-in, temperature cycling, and electrical testing beyond the standard commercial flow used for the AD590KF. The AD590KF is a standard commercial grade and is not screened to MIL-STD-883B.

Can the AD590KF be used as a drop-in replacement for the AD590MF/883B in a military application?

No. The AD590KF is specified only over 0°C to +70°C and is not screened to MIL-STD-883B, so it does not meet the -55°C to +125°C operating range or the reliability screening requirements of the AD590MF/883B. For military or high-reliability applications requiring the extended temperature range and MIL-STD-883B qualification, the AD590MF/883B must be used.

What is the output current transfer function of the AD590KF and AD590MF/883B?

Both devices are two-terminal current-output transducers with a transfer function of 1 µA/K. The output current is proportional to absolute temperature, so at 0°C (273.15 K) the output is approximately 273.15 µA, at 25°C (298.15 K) approximately 298.15 µA, and at 100°C (373.15 K) approximately 373.15 µA. This transfer function is identical for both the AD590KF and AD590MF/883B.